Abstract

ABSTRACTBolt and nut assemblies under tension loading can either fail by bolt fracture or thread failure. The latter failure mode is arguably undesired because it leads to failure at a comparatively low deformation level. Moreover, incipient thread failure is challenging to detect in the case of over‐tightening since the bolt remains in the bolt hole after this type of failure occurs. The failure mode of bolt and nut assemblies is determined by several well‐known factors such as the thread engagement length and the relative strength of the bolt and nut. However, one factor that has received limited attention in the literature is the placement of the nut along the threaded portion of the bolt shank. We have performed a series of direct tension tests on various single M16 bolt and nut assemblies, where the placement of the nut was varied. Some of the assemblies experienced that placing the nut close to the thread run‐out, i.e., near the unthreaded portion of the bolt shank, led to thread failure, whereas placing the nut sufficiently far from the thread run‐out led to bolt fracture. We carried out finite element simulations of the tests in order to further investigate the mechanisms occurring during failure. In the case where the nut was located close to the thread run‐out, the simulations revealed that necking of the bolt shank affected the effective overlap of the internal and external threads. This effect seemed to contribute to thread failure in both tests and simulations.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call