Abstract
The Roseland® hydroxyapatite-coated prosthesis is a total trapeziometacarpal joint prosthesis used for the surgical treatment of thumb basal joint arthritis. The aim of this retrospective study was to evaluate its long-term outcomes. Fifty-one patients (64 thumbs) underwent trapeziometacarpal joint replacement with this prosthesis. The mean follow-up was 12.5 years. Survival rate of the prosthesis was 91%. There was either no pain or only occasional pain in 91% of cases. The mean QuickDASH score was 27.6. Abnormal radiographic findings were present in 70% of cases. Since they were often asymptomatic, no further treatment was carried out. Complications were common (25%) and occurred early on but could often be treated without surgery. The long-term results with the Roseland® HAC prosthesis are satisfactory in terms of pain relief and function. However, the high complication rate is a major concern.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.