Abstract
Current concepts for tricuspid valve surgery recommend concomitant tricuspid valve reconstruction (TVR) utilizing annuloplasty devices over simple suture annuloplasty.
Highlights
Aims/Objectives It is unclear if flexible bands offer the same long-term results like rigid or semi-rigid rings
We aimed to evaluate possible outcome differences between the flexible SJM Tailor Band (FB group) and the CarpentierEdwards rigid MC3-Ring (RR group)
We retrospectively evaluated 141 patients undergoing tricuspid valve reconstruction (TVR) with the MC3-ring or the Tailor Band or suture annuloplasty between 01/11 and 12/13
Summary
Aims/Objectives It is unclear if flexible bands offer the same long-term results like rigid or semi-rigid rings. Results of tricuspid valve reconstruction using a semirigid ring or a flexible band Ivan Aleksic*, Jörg Hoffmann, Michal Glanowski, Ina Schade, Sebastian P Sommer, Marcus Leistner, Armin Gorski, Rainer G Leyh From World Society of Cardiothoracic Surgeons 25th Anniversary Congress, Edinburgh Edinburgh, UK.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.