Abstract

Evidence supporting modular, tapered stems for severe proximal metaphyseal and diaphyseal bone loss is limited. We report our clinical experience with its use for severely deficient femurs. Of 211 revision total hip arthroplasties (THAs), 18 tapered, modular titanium stems were implanted in Paprosky type III and IV femurs. Clinical data were reviewed for function, stability, structural failure and revision surgery at a mean follow-up of 4.5years. The overall survival rate was 94%. One required revision due to infection and subsidence. The mean subsidence was 3.5mm and the mean pre- and post-operative Harris Hip score was 56 and 79, respectively. In surviving cases, patients achieved satisfactory function and there were no mechanical failures. Modular, tapered stems demonstrated acceptable outcomes for management of severe proximal metaphyseal and diaphyseal defects.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.