Abstract
Bracing is an essential part of scoliosis treatment. The standard of brace treatment for patients with scoliosis today is still very variable in terms of brace quality and outcome. The Gensingen brace is a further developed Chêneau brace derivative with individual design, which can be adapted through computer-aided design. This study aims to generate a template to obtain a database for prospective multicenter studies study to analyze the results of high-corrective asymmetric Gensingen brace treatment for patients with adolescent idiopathic scoliosis (AIS). A template for the database was created, which contains the patients' basic data (age, menarcheal status, Risser Sign, curve pattern, and daily brace wearing time), the Cobb angles of curvature, and the cosmetically relevant angles of trunk rotation (ATR). A retrospective review of medical records of patients with AIS, who met the Scoliosis Research Society's inclusion criteria for brace studies, was performed to test the feasibility of the template. Template items were filled in by the researchers. Out of 115 patients between 2014 and 2018, the complete data of 33 patients followed up at least 3 months after complete Gensingen brace weaning could be analyzed. The mean age was 12 years, the mean Cobb angle was 33.6°, and the mean Risser value was 0.7 at the beginning of the treatment. The mean improvement in the Cobb angle on in-brace x-ray imaging was -26.1० (80% of in-brace correction). The Cobb angle of the major curvature changed as follows: curve stabilization was achieved in 7 (21.2%) cases, and curve improvement was achieved in 26 (78.8%) cases. None of the patients showed a curve progression. The Cobb angle was significantly reduced in the brace at the end of treatment and at follow-up evaluation (P<.001). ATR improved significantly for thoracic (P<.001) and lumbar curves (P<.001). The database proved to be informative in the assessment of radiological and clinical outcome parameters. The example data set we have generated can be a helpful tool for professionals who work in clinics but do not store regular patient data. Especially with regard to different patient collectives worldwide, different results may be achieved with the same standards of care. In addition, the results of this study suggest that above-average correction effects with a full-time brace application lead to significant improvements in the Cobb angle after brace treatment has been completed.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.