Abstract

Four-corner arthrodesis with scaphoid excision has been used to reduce pain and preserve functional range of motion for patients with radioscaphoid arthritis. Early results of 4-corner arthrodesis with scaphoid excision using dorsal circular plate fixation are compared with reported results in the literature. We reviewed retrospectively the first 18 four-corner arthrodeses performed with this system by 4 hand surgeons. Two patients had revision surgery for nonunions before the study that were considered failures. Eight patients returned for final radiographs, objective examination, and functional questionnaire. The average follow-up period was 20 months (range, 13-33 mo). These results were compared with reported results in the literature using alternate fixation methods. Radiographic union was achieved in only 3 wrists. Range of motion was 46% that of the opposite normal wrist and grip strength compared with the opposite wrist was 56%. Five patients would have the procedure again and 6 of 8 have returned to their original employment. Four-corner arthrodesis with scaphoid excision using a circular internal fixation plate produced a high number of nonunions. Grip strength and range of motion results also were inferior to those reported in the literature.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call