Abstract

In an open clinical study, a xenon-chloride excimer laser was used for angioplasty of coronary stenoses (n = 48) and chronic total occlusions (n = 56) in 104 patients. Multifiber catheters (4.0F to 5.5F) transmitted 37 to 120 mjoules/mm 2 of fiber surface. Excimer laser angioplasty was successful in 43 patients with a stenosis (89%), followed by percutaneous transluminal coronary angioplasty in 21 patients (49%) to reduce the stenosis to less than 50% luminal narrowing. In 39 patients (70%) with a chronic occlusion (age 1 to 14 months), recanalization by means of excimer laser angioplasty was successful, with subsequent percutaneous transluminal coronary angioplasty performed in 23 patients. Major complications included one perforation, one acute occlusion, and two severe dissections. Six-month angiographic follow-up examinations after successful angioplasty were completed in 40 patients (98%) with stenoses and 34 (94%) with occlusions. Restenosis (> 20% decrease in luminal diameter) occurred in 13 patients (33%) with stenoses and in 16 patients (47%) after angioplasty of a chronic occlusion. These long-term results indicate that restenosis after excimer laser angioplasty of coronary stenoses and chronic total occlusions is similar to reported results of conventional balloon angioplasty.