Abstract

We report on the enhancement of responsivity by more than one order of magnitude of a silicon-based sub-terahertz detector when a mesoscopic dielectric particle was used to localize incident radiation to a sub-wavelength volume and focus it directly onto the detector. A strained-silicon modulation field-effect transistor was used as a direct detector on an incident terahertz beam at 0.3 THz. A systematic study in which Teflon cubes were placed in front of the detector to focus the terahertz beam was performed. In this study, cubes with different sizes were investigated, and an enhancement of the responsivity up to 11 dB was observed for a cube with an edge length of 3.45 mm (or 3.45λ). Electromagnetic simulation results were in good agreement with the experimental ones and demonstrated that the size of the mesoscopic particle plays an important role in focalizing the electric field within an area below the diffraction limit. This approach provides an efficient, uncostly, and easy to implement method to substantially improve the responsivity and noise equivalent power of sub-terahertz detectors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.