Abstract

BackgroundThe FROM-16 is a generic family quality of life (QoL) instrument that measures the QoL impact of patients’ disease on their family members/partners. The study aimed to assess the responsiveness of FROM-16 to change and determine Minimal Important Change (MIC).MethodsResponsiveness and MIC for FROM-16 were assessed prospectively with patients and their family members recruited from outpatient departments of the University Hospital Wales and University Hospital Llandough, Cardiff, United Kingdom. Patients completed the EQ-5D-3L and a global severity question (GSQ) online at baseline and at 3-month follow-up. Family members completed FROM-16 at baseline and a Global Rating of Change (GRC) in addition to FROM-16 at follow-up. Responsiveness was assessed using the distribution-based (effect size-ES, standardized response mean -SRM) and anchor-based (area under the receiver operating characteristics curve ROC-AUC) approaches and by testing hypotheses on expected correlation strength between FROM-16 change score and patient assessment tools (GSQ and EQ-5D). Cohen’s criteria were used for assessing ES. The AUC ≥ 0.7 was considered a good measure of responsiveness. MIC was calculated using anchor-based (ROC analysis and adjusted predictive modelling) and distribution methods based on standard deviation (SD) and standard error of the measurement (SEM).ResultsEighty-three patients with 15 different health conditions and their relatives completed baseline and follow-up questionnaires and were included in the responsiveness analysis. The mean FROM-16 change over 3 months = 1.43 (SD = 4.98). The mean patient EQ-5D change over 3 months = −0.059 (SD = 0.14). The responsiveness analysis showed that the FROM-16 was responsive to change (ES = 0.2, SRM = 0.3; p < 0.01). The ES and SRM of FROM-16 change score ranged from small (ES = 0.2; SRM = 0.3) for the distribution-based method to large (ES = 0.8, SRM = 0.85) for anchor-based methods. The AUC value was above 0.7, indicating good responsiveness. There was a significant positive correlation between the FROM-16 change scores and the patient’s disease severity change scores (p < 0.001). The MIC analysis was based on data from 100 family members of 100 patients. The MIC value of 4 was suggested for FROM-16.ConclusionsThe results of this study confirm the longitudinal validity of FROM-16 which refers to the degree to which an instrument is able to measure change in the construct to be measured. The results yield a MIC value of 4 for FROM-16. These psychometric attributes of the FROM-16 instrument are useful in both clinical research as well as clinical practice.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call