Abstract

A polymer/silica hybrid 2×2 directional coupler (DC) Mach–Zehnder interferometer (MZI) thermo-optic (TO) switch is designed and carefully fabricated. Because of larger thermal conductivity relative to the polymer, silica is utilized as bottom cladding for accelerating heat release. The fabricated TO switch with polymer/silica hybrid structure exhibits low power consumption, less than 7.2mW, fast rise time of about 106μs and fast fall time of about 93μs. This response time is reduced by 40% compared to that of the TO switch with polymer waveguide.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.