Abstract

To investigate the behavior of piles and the performance of the mechanically stabilized earth (MSE) walls under static and cyclic lateral loading, six reduced-scale model tests of single and group piles within the MSE walls were conducted inside a test box. In the single pile tests, a hollow aluminum tube as a pile was placed at a distance of 2D or 4D (D is pile diameter) behind the wall facing, while in the group pile tests, the piles were only placed at the distance of 2D with a spacing of 3.3D between the piles. The piles were subjected to static lateral loading only and cyclic lateral loading followed by static loading until failure. The test results showed that the lateral load capacity of each pile in the group pile test was approximately 60% that of the single pile, while the wall facing displacements and the geogrid strains in the group pile test were larger than those in the single pile test. The lateral pile capacity, the wall facing displacement, the strain in the geogrid, and the lateral earth pressure behind the wall facing in the static and cyclic loading tests were evaluated at the pile head displacement equal to 20%D.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call