Abstract
Editor—We read with interest the editorial by van Zundert and colleagues1Van Zundert AAJ Gatt SP Kumar CM Van Zundert TCRV Pandit JJ Failed supraglottic airway: an algorithm for suboptimally placed supraglottic airway devices based on videolaryngoscopy.Br J Anaesth. 2017; 118: 645-649Abstract Full Text Full Text PDF PubMed Scopus (35) Google Scholar in the recent issue of British Journal of Anaesthesia. We strongly commend the authors for highlighting the problem of suboptimal laryngeal mask airway (LMA) placement. As a single specialty ear, nose, and throat hospital, we are perhaps in a unique position in that the majority of our caseload is shared airway using first-generation flexible LMAs. Since the flexible LMA was introduced at our hospital in 1990, we estimate that we have performed >135 000 ENT operations, with 80–85% performed with flexible LMAs. This includes a large number of shared airway procedures, such as tonsillectomy. These procedures, in themselves, are a good test of LMA function, requiring the maintenance of optimal ventilation whilst also protecting the larynx from blood and debris. We would, however, like to discuss a number of points raised in the article, including the anatomical relationship between the LMA and patient, rescue manoeuvres, and the use of videolaryngoscopy after LMA insertion. In both the original article2Van Zundert AAJ Gatt SP Kumar CM Van Zundert TCRV Vision-guided placement of supraglottic airway device (SAD) prevents airway obstruction: a prospective audit.Br J Anaesth. 2017; 118: 462-463Abstract Full Text Full Text PDF PubMed Scopus (14) Google Scholar and the subsequent editorial,1Van Zundert AAJ Gatt SP Kumar CM Van Zundert TCRV Pandit JJ Failed supraglottic airway: an algorithm for suboptimally placed supraglottic airway devices based on videolaryngoscopy.Br J Anaesth. 2017; 118: 645-649Abstract Full Text Full Text PDF PubMed Scopus (35) Google Scholar the authors made a number of assertions regarding the relationship between anatomy and LMA function, which they have used as the basis of a grading system. Although we agree that the epiglottis can cause partial or complete obstruction of the LMA, it does not have to be seated on the anterior aspect of the rim of the proximal LMA cuff to function correctly. Indeed, in patients with a short laryngeal inlet it may be preferable to have part of the epiglottis within the bowl of the LMA. Downsizing to a smaller LMA to align its posterior rim with the epiglottis, as suggested by the authors’ algorithm, could lead to deterioration in the overall LMA seal. In such instances, a distally sited LMA may open posterior to the arytenoids, causing obstruction to gas flow. We agree that a jaw thrust greatly increases the chances of achieving a well-positioned LMA. When used in combination with Brain's original description of LMA insertion,3Brain AIJ Proper technique for insertion of the laryngeal mask.Anesthesiology. 1990; 72: 474-477Crossref PubMed Scopus (61) Google Scholar using the index finger to guide the LMA cuff into the hypopharynx, first-time insertion success rates are maximized. If initial attempts fail, the narrow shaft of the flexible LMA facilitates the use of Magill forceps to guide the LMA beyond the epiglottis under direct laryngoscopy. The authors have suggested videolaryngoscopy to confirm correct LMA placement. However, we question this part of the algorithm, because minimal laryngoscopic force alters the relationship between the epiglottis, base of tongue, and LMA, potentially displacing it from its original position. Thus, attempting to define a grading system on this basis may lead to misdiagnosis of the cause of suboptimal function. Other issues not addressed in the algorithm are the presence of laryngospasm because of a light plane of anaesthesia, or vocal cord squeeze from an overinflated LMA cuff. In both instances, the position of the LMA may be anatomically correct, but oropharyngeal leak pressures will be greatly reduced. Corrective measures, such as laryngoscopy with or without Magill forceps, may therefore be counter-productive. In summary, we believe that this editorial1Van Zundert AAJ Gatt SP Kumar CM Van Zundert TCRV Pandit JJ Failed supraglottic airway: an algorithm for suboptimally placed supraglottic airway devices based on videolaryngoscopy.Br J Anaesth. 2017; 118: 645-649Abstract Full Text Full Text PDF PubMed Scopus (35) Google Scholar has highlighted the current shortfalls in LMA practice. However, we do not believe a grading system based on videolaryngoscopy is the correct approach to an issue not easily categorized. Instead, appropriate training and practice, focusing on correct insertion technique, may be more beneficial. A.B. invented the Laryngeal Mask Airway. No other conflicts of interest declared.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.