Abstract

• The model was made purposely simple to focus attention on the qualitative influence of stiffness on reinforcement loads. • Using numerical models to infer quantitative performance of actual MSE walls must be undertaken with caution and skill. • Small changes in numerical model details can give widely different estimates of reinforcement loads. • The veracity of any numerical model should be based on comparisons with more than one physical wall of realistic height. • The accuracy of design methods must be assessed using measured loads from full-scale walls, not numerical models.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.