Abstract
We have measured the thermal response of a superconductor–normal metal–superconductor (SINIS) tunnel junction structure at substrate temperature ∼60 mK by directly heating the electron system in the normal metal island. In our structure, we find the response time is determined by the electron–phonon coupling in the electron temperature range 300– 600 mK . By using AC heating, the cut-off frequency caused by this response time has been measured, showing that SINIS structures operate as a thermometer up to a few MHz in this temperature range.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Physica E: Low-dimensional Systems and Nanostructures
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.