Abstract
A full-scale, timber-framed, truss, hip roof was subjected to simulated wind loads. Spatially and temporally varying pressures were applied using an array of 58 Pressure Loading Actuators, together with air-boxes covering all roof surfaces. Load cells were incorporated at the top of the wall frame, just below the top plate, to measure the reactions at the toe-nailed roof-to-wall connections. Changes in influence functions and load sharing between adjacent trusses were observed to occur during withdrawal (slip) of the toe-nail connections caused by large magnitude, short duration peak pressures. Even for relatively small displacements, it was observed that the effective tributary area is substantially increased by the incremental withdrawals. This acts to increase the resilience of the roof by allowing more limber and/or more highly loaded connections to transfer loads to stiffer and/or less highly loaded connections. Influence functions, measured both prior to and following damage, were able to predict this behaviour.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.