Abstract

The Two Arm Photon Spectrometer TAPS — comprising 384 plastic-BaF 2 scintillator telescopes - was tested with monochromatic photons in the energy range between 45 and 790 MeV. The energy resolution for a collimated photon beam hitting the central detector module was determined to σ/E = 0.59% × E γ − 1 2 + 1.9% (E γ given in GeV) . For the the fast scintillation component alone σ/E = 0.79% × E γ − 1 2 + 1.8% has been measured. The position resolution of the point of impact amounts to Δx = 2 cm (FWHM) at the highest energies which corresponds to 30% of the diameter of an individual module. Monte Carlo simulations using the code GEANT3 are in good agreement with the experimental results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call