This article presents the experimental results of stone wool–layered sandwich constructions, with either steel or gypsum claddings, tested under four different heating exposures: 7 kW/m2 incident radiant heat flux exposure, 60 kW/m2 incident radiant heat flux exposure, parametric time–temperature curve exposure and ISO 834 standard time–temperature exposure. The test apparatus used were a movable radiant panel system, a mid-scale furnace (1.5 m3) and a large-scale furnace (15 m3). The results show that reduced-scale tests are capable of reproducing the heat transferred through the construction at large scale provided there is limited mechanical degradation. The results indicate that the availability of oxygen is fundamental to the fire behaviour of the sandwich composites tested. Reactions occurring in stone wool micro-scale testing, such as oxidative combustion of the binder or crystallisation of the fibres, have a limited effect on the temperature increase when wool is protected from air entrainment.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.