Abstract

The rocking behavior of self-centering mass plywood panel (MPP) walls was investigated with and without the use of supplementary energy dissipation systems. Two energy dissipation systems were tested. The first system used a kinematically expanding hysteretic damper (KE-HD), whereas the second system used slip friction connections (SFCs). The reviewed energy dissipating systems were used in a self-centering system comprising one unbonded posttensioned (PT) hold-down rod on each side of the MPP walls. The cyclic performance of the PT and the hybrid MPP specimens was investigated through a series of full-scale quasi-static cyclic tests. The test results demonstrated the viability of the investigated energy dissipaters in self-centering MPP rocking systems. Results further indicate that hybrid specimens with SFC dissipate more energy and provide higher strength than those with KE-HDs, however, with higher residual drift.