Abstract
In this study the behavior of reinforced concrete members with rectangular spiral shear reinforcement under cyclic loading is experimentally investigated. In this direction two pairs of specimens are tested. The first pair of specimens comprises two exterior beam-column joints while the second one comprises two column specimens. The first specimen of each pair has rectangular spiral shear reinforcement whereas the latter has common stirrups. Both beam-column specimens have been suffered the same full cyclic deformation with increasing amplitude and 2 full cycles at every step. Also, both column specimens have been suffered the same increasing full cyclic deformation with 2 full cycles at every step. The results of the tested specimens reinforced with rectangular spiral reinforcement are compared with the results of the specimens reinforced with stirrups, in terms of maximum loading and energy absorption per step, and ductility capacity. From the observed responses of the tested specimens it can be deduced that the use of rectangular spiral reinforcement in the reinforced concrete members improved the seismic capacity of all the examined specimens.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.