Abstract

Ventilatory responses to CO2 inhalation and CO2 infusion were compared in the awake dog. The CO2 was introduced directly into the systemic venous blood via a membrane gas exchanger in a femoral arteriovenous shunt circuit, and the extracorporeal blood flow, QX, was maintained constant at one of two rates: low, 0.5 l/min; or high, 2.0 l/min. A total of 13 experiments was performed in four dogs comprising 50 control and 25 inhalation and infusion observations at each of the two flow rates. Comparison of CO2-response curve slopes, S = delta V E/delta PaCO2, between CO2 inhalation and infusion showed no significant difference either within or between flow rates. The mean value of S for all conditions was 1.88 l/min per Torr with a 95% confidence interval of 1.66 -2.14. An independent additive ventilatory drive amounting to 28% of low-flow control VE was found at the highflow rate. We conclude that at constant blood flow the responses to both CO2 inhalation and infusion are hypercapnic and not significantly different.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.