Abstract
Respiratory motion correction is necessary for the quantitative analysis of liver contrast-enhanced ultrasound (CEUS) image sequences. Most respiratory motion correction methods are based on the dual mode of CEUS image sequences, including contrast and grayscale image sequences. Due to free-breathing motion, the acquired two-dimensional (2D) ultrasound cine might show the in-plane and out-of-plane motion of tumors. The registration of an entire 2D ultrasound contrast image sequence based on out-of-plane images is ineffective. For the respiratory motion correction of CEUS sequences, the reference image is usually considered the standard for the deletion of any out-of-plane images. Most methods used for the selection of the reference image are subjective in nature. Here, a quantitative selection method for an optimal reference image from CEUS image sequences in the B mode and contrast mode was explored. The original high-dimensional ultrasound grayscale image data were mapped into a two-dimensional space using Laplacian Eigenmaps (LE), and K-means clustering was adopted. The center image of the larger cluster with a near-peak contrast intensity was considered the optimal ultrasound reference image. In the ultrasound grayscale image sequence, the images with the maximum correlations to the reference image in the same time interval were selected as the corrected image sequence. The effectiveness of this proposed method was then validated on 18 CEUS cases of VX2 tumors in rabbit livers. Correction smoothed the time-intensity curves (TICs) extracted from the region of interest of the CEUS image sequences. Before correction, the average of the total mean structural similarity (TMSSIM) and the average of the mean correlation coefficient (MCC) from the image sequences were 0.45±0.11 and 0.67±0.16, respectively, and after correction, the average TMSSIM and MCC increased (P<0.001) by 31% to 0.59±0.11 and by 21% to 0.81±0.11, respectively. The average deviation value (DV) index of the TICs from the image sequences prior to correction was 92.16±18.12, and correction reduced the average to 31.71±7.31. The average TMSSIM and MCC values after correction using the mean frame of the reference image (MBMFRI) were clearly lower than those after correction using the proposed method (P<0.001). Moreover, the average DV after correction using the MBMFRI was obviously higher than that after correction using the proposed method (P<0.001). The breathing frequency of rabbits is notably faster than that of human beings, but the proposed correction method could reduce the effect of the respiratory motion in the CEUS image sequences. The reference image was selected quantitatively, which could improve the accuracy of the quantitative analysis of rabbit liver CEUS sequences using the reference image method based on the current standard of manual selection and the MBMFRI. Thiseasy-to-operatemethod can potentially be used in both animal studies and clinical applications.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.