Abstract
We used the interrupter technique to measure the resistance Rinit (equal to the initial change ΔPinit in tracheal pressure divided by flow at interruption) during expiration in six normal anaesthetized-paralyzed cats. By performing interruptions at different points in expiration we found Rinit in each cat to be linearly dependent on flow. By allowing the cats to expire through two different resistances we were also able to demonstrate a volume dependence of Rinit in four of the cats. In addition, we obtained a secondary pressure change Δdif in each cat, as the magnitude of the slow change in tracheal pressure in the 2 sec following interruption of flow. ΔPdif was approximately constant over most of the expired volume range, and represented the difference between the static elastic recoil pressure of the respiratory system and the pressure driving flow at any volume during a passive expiration. ΔPdif became larger than ΔPinit towards the end of expiration. Since previously used methods for measuring respiratory system resistance have employed varying combinations of ΔPinit and ΔPdif as the resistive pressure drop, it is clear that measurements of resistance must be made with standard techniques under standard conditions if they are to be compared.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.