Abstract

The search for an improved or alternative instrument that will be able to measure occupational exposure more accurately and more reliably is continuing. Several developments have been taken place overseas with regard to real-time monitoring instruments for personal exposure assessment. In the light of these developments, the respirable dust dosimeter (RDD) described by Volkwein et al. (2000) appeared to be a promising development. RDD measures the dust exposure in differential pressure units (mm of Hg) indicating that it is a surrogate for the mass of dust on a gravimetric filter. This paper describes the results of an evaluation on theRDDunder laboratory conditions before evaluating them in underground mines for personal dust exposure assessment.The laboratory study has shown that there is a potential for the RDD sampler as a screening tool for engineering sample purposes. However, RDD was comparatively expensive during the research exercise costing approximately 16UK Pounds per RDD tube. Further, there was no well-accepted procedure on collect dust samples using RDD tube for further quartz analysis. Finally, due to its reasonable estimates of real-time cumulative shift dust exposure, and its small lightweight package, the RDD was further recommended for personal sampling purposes in the SouthAfrican mines.

Highlights

  • The search for an improved or alternative instrument that will be able to measure occupational exposure more accurately and more reliably is continuing

  • There was no well-accepted procedure on collect dust samples using respirable dust dosimeter (RDD) tube for further quartz analysis

  • There is a significant difference in the measured dust levels between SA sampler and Dorr-Oliver sampler when operated according to the same size-selective curve (ACGIH/ISO/CEN)

Read more

Summary

Introduction

The search for an improved or alternative instrument that will be able to measure occupational exposure more accurately and more reliably is continuing. Several developments have been taken place overseas with regard to real-time monitoring instruments for personal exposure assessment. This paper describes the results of an evaluation on the RDD under laboratory conditions before evaluating them in underground mines for personal dust exposure assessment. Several developments have been taken place overseas with regard to near-real-time monitoring instruments for personal exposure assessment. In the light of these developments, the respirable dust dosimeter (RDD) developed by the National Institute of Occupational Safety and Health (NIOSH) appeared to be a promising instrument for personal dust exposure measurement. This paper describes the laboratory investigations into the newly developed RDD tube for personal exposure assessment in SouthAfrican mines. In order for the introduction of the new dust-monitoring instruments for personal sampling in underground mines, they were required to meet the following criteria:

Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.