Abstract

The purpose of this study was to investigate the relative influence of scatter, attenuation, depth-dependent collimator response and finite spatial resolution upon the image characteristics in cardiac single-photon emission tomography (SPET). An acquisition of an anthropomorphic cardiac phantom was performed together with corresponding SPET Monte Carlo simulations. The cardiac phantom and the Monte Carlo simulations were designed so that the effect of scatter, attenuation, depth-dependent collimator response and finite spatial resolution could be studied individually and in combination. The impact of each physical effect and of combinations of effects was studied in terms of absolute and relative quantitative accuracy, spatial resolution and signal-to-noise ratio (SNR) in the resulting images. No corrections for these effects were assessed. Results obtained from Monte Carlo simulations and real acquisitions were in excellent agreement. Attenuation introduced about 90% activity underestimation in a 10-mm-thick left ventricle wall while finite spatial resolution alone introduced about 30% activity underestimation. Scatter had a negligible impact on quantitative accuracy in the recontructed slices when attenuation was present. Neither bull's eye map homogeneity nor contrast between a hot and a cold region were affected by depth-dependent collimator response or finite spatial resolution. Bull's eye map homogeneity was severely affected by attenuation but not by scatter. Attenuation and scatter reduced contrast by about 20% each. Both attenuation and scatter increased the full-width at half-maximum (FWHM) characterizing the spatial resolution of the imaging system by approximately 1 mm each but the main effect responsible for the observed 11-mm FWHM spatial resolution was the depth-dependent collimator response. SNR was reduced by a factor of approximately 2.5 because of attenuation, while scattered counts increased SNR by approximately 10%. In conclusion, the quantification of the relative influence of the different physical effects showed that attenuation is definitely the major phenomenon affecting cardiac SPET imaging accuracy, but that finite spatial resolution, scatter and depth-dependent collimator response also contribute significantly to the errors in absolute and relative quantitation and to the poor spatial resolution.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call