Abstract

PurposeTo present a modified technique for secure tightening and fixing of multilayer amniotic membranes in deep or perforating corneal ulcers. ObservationsThe modified procedure for application and fixation of multilayer amniotic membranes is retrospectively described step by step, and the results of three patients treated with this technique were retrospectively analysed and presented.The modification consists basically in fixing the inlays with one mini-overlay that is sutured intracorneally with resorbable and running Vicryl 10.0, before a corneoscleral overlay is fixed on top conjunctivally with a running nylon 10.0 suture. The resorbable Vicryl suture is left in place permanently. Conclusions and ImportanceThe method described avoids any risk of destroying or displacing the inlays by removing sutures later. In each of the three patients demonstrated as case reports the cornea remained stable throughout the 3- to 5-month follow-up period. This modified technique represents a very useful auxiliary means of treating deep or perforating non-infectious corneal ulcers.