Abstract

The technique of resonant ultrasound spectroscopy (RUS) was used to measure the second-order elastic constants of hydrated human dentin. Specimens were placed between two transducers, and the resonant frequencies of vibration were measured between 0.5 and 1.4 MHz. The elastic constants determined from the measured resonant frequencies in hydrated dentin exhibited slight hexagonal anisotropy, with the stiffest direction being perpendicular to the axis of the tubules ( E 11=25.1 GPa). This hexagonal anisotropy was small ( E 33/ E 11=0.92), and almost disappeared when the specimens were dried. In addition, there was a pronounced anisotropy in the Poisson's ratio of wet dentin: ν 21=0.45; ν 31=0.29. With drying in air, this anisotropy vanished: ν 21= ν 31=0.29. The isotropic Young's modulus of dried dentin was 28.1 GPa. RUS shows promise for determining the elastic constants in mineralized tissues.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.