Abstract

Experimental and theoretical results are described on the enhancement of optical second harmonic generation (SHG) and mixing in KDP by the use of optical resonance. Both resonance of the harmonic and of the fundamental are considered. Large enhancements are possible for resonators with low loss. Using a planoconcave harmonic resonator containing 1.23 cm of KDP, the authors achieved a loss < 4 percent per pass. This resulted in an enhancement of ∼ 500 times the harmonic power internal to the resonator and ∼ 10 times external to the resonator. When resonating, the fundamental enhancements of ∼ 5 were observed. The theory includes the effect of double refraction. This results in a coupling coefficient of the generated harmonic power to the transverse modes of the harmonic resonator. The experimental results are in substantial agreement with the theory.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.