Abstract
Observation alone is advised only for primary spontaneous pneumothoraces with less than 20 percent of the lungs collapsed. In such cases, it is the resorption capabilities of the visceral pleura that are solely relied upon. The AIM of the present experimental study was to demonstrate the capabilities of the pleura for pneumothorax resolution by room air. The study was conducted with six laboratory animals (New Zealand white rabbits, weighing 2.5-3.5 kg), in which right total pneumothorax was induced. Conventional chest X-rays at intervals of 2 days were used to monitor the changes in the size of the pneumothorax until its final resolution. The size of the pneumothorax was estimated by the Light index. Total resolution of the pneumothorax occurred within 12 days after it was induced. The average rate of pneumothorax resolution was 6.63% (SEM +/- 0.20)/daily. The study imitates initial clinical observation in pneumothorax. Despite the fact that the study demonstrates resolution of total pneumothorax (100%), observation only is inappropriate as a treatment modality in patients with more than 20% collapse of the lung.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.