Abstract

Essential is that creep strain monitoring sensors need to be of a rugged design well able to endure the demanding conditions related to the environment of high-pressure steam pipes and other power plant components. A useful monitoring method employs the E.ON UK ARCMAC gauge system with a capability of both uniaxial and biaxial strain measurements. The choice of monitoring location, for example, can be to welded pipe sections and other known early failure locations on steam pipes and other plant components. The ARCMAC system has been refined over the years to improve the accuracy of measurement. In this paper, recent developments have allowed the strain measurement accuracy to be improved to 64 micro-strain with an error of <10%. Also, recently, high temperature trials of the combined ARCMAC/DIC have commenced and early findings are reported.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.