Abstract

Figures of merit are introduced for estimation of achievable resolution of surface plasmon (SP) sensors by modulation type. The resolution of SP sensors in the Kretschmann’s geometry is estimated by numerical simulation for combinations of silver (Ag), copper (Cu), aluminum (Al), chromium, and titanium layers with a gold (Au) layer in the ultraviolet (UV), visible, and infrared (IR) regions in cases of detecting the change of the refractive index of water and the presence of an adsorption layer in water. SP biosensors with angular modulation based on Al exhibit low resolution in the UV region; Ag, Au, and Cu biosensors show best resolution in the visible region. Biosensors with intensity modulation demonstrate high performance in the near IR by Ag, Au, and Cu metals, and in the UV by Al.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.