Abstract

In composite beam design, headed stud shear connectors are commonly used to transfer longitudinal shear forces across the steel-concrete interface. This paper describes the structural performance of shear connection in composite beams with profiled steel sheeting. An accurate and efficient nonlinear Finite Element (FE) model was developed to study the behavior of headed stud shear connectors welded through the deck. The concrete slab considered in this article uses profiled steel sheeting with ribs perpendicular to the longitudinal axis of the steel beam. The material nonlinearities were included in the FE model. The concrete was modeled considering a damaged plasticity model available in ABAQUS software. The results obtained from FE analysis were verified against experimental results. A parametric study was conducted to observe the effects of changing of both the stud position inside the rib of profiled steel sheeting and the concrete strength on the resistance of the stud shear connector. The shear resistance of stud connectors obtained from the FE analysis and many experimental push-out tests whose results are available in the literature were used as a database to compare with design shear resistance calculated using AISC-LRFD and Eurocode 4. It is found that the shear resistance of stud connectors, obtained from the design rules specified in these codes, in some cases is greatly underestimated, and in other cases significantly overestimated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.