Abstract

This study presents the development and calibration of resistance factors for the serviceability limit state (SLS) condition (φSLS) used in the load and resistance factor design (LRFD) of deep foundations. The performance function was established based on load corresponding to tolerable displacement (Qδtol) and design load (Qd). A dataset of published full-scale load tests including projects from Texas, Missouri, Arkansas, Louisiana, and New Mexico was compiled and consisted of 60 load test cases comprising 33 driven piles and 27 drilled shafts. Resistance factors for SLS conditions were calibrated for tolerable displacements using both the Monte Carlo simulation (MCS) and the First Order Second Moment (FOSM) approaches. From the calibration study, resistance factors at SLS conditions were obtained ranging from 0.33 to 0.62 using FOSM method and 0.37 to 0.67 using the MCS for driven piles. In the case of drilled shafts, SLS resistance factors ranged from 0.37 to 0.77 following the FOSM method and 0.41 to 0.86 based on MCS.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.