Abstract

This research investigates practical methods to improve the efficiency of natural ventilation in residential units of multi-family high-rises without additional areas. Typical studio- and one-bedroom-types of small units were redesigned using: 1) air post, 2) transom window, 3) buffer space with one corridor opening and 4) buffer space with two corridor openings. The simulation study using a CFD program to reveal that the indoor average air velocity coefficient (Cv ) in the best redesigned case (0.46) significantly improves from the base case (0.01). The paper demonstrates an example of application to an actual climate in Bangkok, Thailand. It was found that the proposed redesign using buffer spaces can considerably help upgrade the living conditions of the occupants in terms of both thermal comfort (24 hours vs. 0 hours in the comfort zone per day) and indoor air quality (24 hours vs. 8–17 hours that pass the minimum ventilation requirement per day) in the transitional month of February.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.