Abstract

Improving the energy efficiency of the residential building stock has increasingly been promoted by policy makers as a means of reducing energy demand in the residential sector. We review the literature on some non-energy impacts of energy efficiency retrofitting measures aimed at increasing the air tightness and thermal insulation of residential properties. Specifically, we review the impact of retrofitting measures on indoor pollutants, mould growth, attenuation of radio signal and overheating. We show that without the provision of adequate ventilation, increased air tightness can result in higher levels of indoor pollutants and mould growth. Similarly, we show that in certain circumstances thermal insulation has the potential to result in increased signal attenuation and overheating. We detail the policy implications of these findings and outline policy actions that have been implemented in case study countries where these consequences have been identified as potential issues.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.