Abstract
AbstractThe emerging global climate change policies have necessitated the strategic need for prudent management of produced contaminants and, with cold flaring being no more the best option, Carbon Capture Utilization & Storage (CCUS) technology provides opportunity for development of high CO2 contaminant fields. A typical CO2 sequestration project comprises capturing CO2 by separating from produced hydrocarbons followed by injection of CO2 into deep geological formations for long term storage. While injection ofCO2 may continue over tens of years, the long-term containment needs to be ascertained for thousands of years. Several geological and geophysical factors along with the existingwells need to be evaluated to assess the potential risks for CO2 leakage that maychallenge the long-term containment.This study considers a depleted carbonate field located offshore Sarawak as a possible long-term CO2 storage site. Elements that may lead to possible leakage of CO2over time are the existing faults or fractures, development of new fractures/faults during injection, caprock failure due to pressures exceeding fracture pressure during/after injection and possible leakage through existing wells. The risk assessment process includes identification and mapping of faults and fracture networks, mapping of seals, evaluation of seismic anomalies and gas while drilling records, pore-pressure analysis, laboratory experiments for analyzing changes in geomechanical & geochemical rock properties and well integrity of existing wells. All these parameters are cross correlated, and qualitative risk categorization is carried out to determine the robustness of the reservoir for long term CO2 storage.The evaluation of available data indicates less frequent faulting occur only towards the flank with no seismic anomalies associated with them. Some seismic anomalies are observed at shallower levels, however their impact on the reservoir and overburden integrity is assessed to be minimum. There are four shale dominated formations mapped in the overburden section, which will act as potential seals. Estimated fracture pressures for the potential seals ranges between 6200-9280 psia for the deepest seal to 2910-4290 psia for the shallowest. Therefore,it is interpreted that if the post injection reservoir pressure is kept below the initial reservoir pressure of 4480 psia, it would not hold any threat to the caprock integrity.Leakage rate riskalong the existing wells was determined based on well log data. Well integrity check of legacywells helped identify two abandoned wells for rigorous remediation to restore their integrity.The subsurface risk analysis is critical to ascertain the long-term containment of injectedCO2. The integrated subsurface characterization and well integrity analysis approach adopted in this work can be applied to any other field/reservoir to validate its robustness for long-term CO2 injection and storage.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.