Abstract

This paper has completed the simulation of the X-band 1 MW klystron electronic optical system, and optimized the electron gun and focusing system respectively. The electron gun adopts a single electron beam scheme. The voltage and current of the beam is 80 kV and 45 A respectively, the perveance is about 2.0 μP , and the average emission current density of the cathode is 6.81 A/ cm 2. The focusing system adopts the design of electromagnetic focusing, and the maximum magnetic field in the uniform area is about 0.33 T. The calculation results show that the distribution of the electric field lines in the electron gun area is uniform, the fluctuation of the electron beam is uniform, and the DC pass rate of the electron beam reaches 100%, which meets the design requirements.