Abstract

In all the designs of air transport ducts, it is necessary to know the divided-flow characteristics when particles are flowed by air streams from a main duct to branch ducts. Then, in this report, we flowed particles through the rectangular air duct installed horizontally and studied the divided-flow characteristics between particles and air. As a result, the following conclusions have been reached : i) When particles are to be conveyed from a horizontal main duct to branch ducts, we can hardly attain our object of the divided-flow by air regulation alone, unless we install a damper at the take-offs of a duct. ii) If we install a damper at the take-offs of a duct and use together with the control of the air flow rate, we can regulate comprehensively the flow rate of particles. iii) We got a damper angle offering maximum divided-flow rate of particles for a given air flow, and showed experimental formulae concerning the damper angle and the divided-flow rate of particles.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.