Abstract

A 350MW heat supply unit in a power plant encountered abnormal vibration of IP rotor bearing during cold start after overhaul. By analyzing the vibration data in the start-up process, the reason for abnormal vibration was found out to be excessive vibration of IP rotor passing through critical speed and rubbing between IP rotor and casing. Through the field high dynamic balancing test and adopting the most suitable operation control mode of this type of heat supply unit, the abnormal vibration of the unit was eliminated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.