Abstract

High pressure governing valve is modelled by elliptic equations, and verified through the comparison with the literature data. Then a 660MW ultra-supercritical steam turbine with throttle steam distribution mode is modelled to explore the efficiency of HP cylinder and the unit’s economic under different loads with different operation strategies. Analysis shows that the valve opening is an important factor that impacts the heat rate and the valve in 30%-40% opening should be recommended for operation. According to the requirements of grid frequency adjustment, the proposed operation strategies can improve the units’ economic performance and enhance the ability of deep peak regulation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.