Abstract

The heat transfer characteristic of typical thermal bridge is tested, and numerical simulation is carried out by ANSYS finite element analysis software. The accuracy of two-dimensional heat transfer numerical simulation method is verified through comparative analysis. It can be seen that the temperature simulated values of each measuring point are consistent with the variation trend of the measured values, and the temperature deviations are not more than 10%. This shows that the finite element numerical simulation method can accurately analyze the two-dimensional heat transfer characteristics of the thermal bridge.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.