Abstract
The coupled variance reduction method based on adjoint calculation has a good variance reduction effect when solving the source-detector problem. This paper incorporates the Automatic Importance Sampling (AIS) method into the adjoint Monte Carlo method and then proposes a coupled variance reduction method based on the AIS adjoint Monte Carlo method. The result shows that the total flux deviation between the AIS adjoint Monte Carlo method and the original adjoint method is 0.13%, indicating good agreement and verifying the accuracy of the AIS adjoint method. In this paper, the AIS adjoint Monte Carlo method is applied to the calculation of a commercial reactor shielding example, and four sets of source bias and weight window parameters of the AIS adjoint calculation are used as calculation examples. The maximum statistical error is less than 5.00%, and the relative deviation from the measured value is within 20.00%. Generally, the calculation efficiency of AIS-CADIS is slightly better than that of CADIS.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.