Abstract
Leakage causes of branch pipe of unit thermal networks were discussed based on macroscopic observation, chemical composition analysis, metallurgical microstructure inspection, mechanical property tests, SEM and EDS analysis. The experimental results showed that frequent contact of outer pipe wall with corrosion media and thermal fatigue load led to early crack of the pipe. During compression test, the crack propagated under increased compression stress and burst finally. Suggestions were provided to prevent similar events happening.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.