Abstract

The effect of cosolvent on trace free water in the determination of the contamination degree of jet fuel was investigated. The interference of trace free water on the automatic particle counter can be eliminated by adding isopropanol as a cosolvent to the measured oil sample. Isopropanol can dissolve trace free water in oil. Addition of isopropanol could stabilize the pollution grade of particles with size ≥30 μm (c) at the same level, which is most obviously affected by free water without isopropanol. The standard uncertainty u(X1) is slightly reduced with the addition of isopropanol, and the repeatability and accuracy of the automatic particle counting method are obviously improved. The results show that isopropanol should be added as a cosolvent to eliminate the interference of free water when the contamination degree of jet fuel oil samples with obvious free water is determined by the automatic particle counting method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.