Abstract
The synchronization control performance of the Fieldbus control system (FCS) is an important guarantee for the completion of multi-axis collaborative machining tasks, and its synchronization control accuracy is one of the decisive factors for the machining quality. To improve the synchronization control accuracy of FCS, this paper first makes a comprehensive analysis of the factors affecting synchronization in FCS. Secondly, by analyzing the communication model of linear Ethernet, a distributed clock compensation method based on timestamps is proposed to solve the asynchronous problem of communication data transmission in the linear ethernet bus topology. Then, based on the CANopen application layer protocol, the FCS communication and device control task collaboration method is proposed to ensure the synchronous control of multiple devices by FCS. Finally, an experimental platform is built for functional verification and performance testing of the proposed synchronization method. The results show that the proposed synchronization method can achieve a communication synchronization accuracy of 50 ns and a device control synchronization accuracy of 150 ns.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.