A new method to detect intermittent faults in FPGA (field programmable gate array) of BGA (ball grid array) packages is presented. Inject proper current into measured IO port via sensor circuit, the intermittent faults will arouse impedance of the solder-joint to change intermittently, the voltage of solder-joint will also change intermittently, the fault information can be obtained through regulating the voltage signal. Compared with current monitoring method based on degradation model, this scheme is more reliable and accurate. It can prevent the catastrophic faults caused by failure of the FPGA solder-joints effectively, as well as economize the maintenance cost.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.