Abstract

The color gamut volume (CGV) and light efficiency of a four-primary display system were theoretically simulated with different wavelength configuration. Given the wavelengths of the blue and red primaries, we optimized the other two primary colors; the wavelength set with the largest CGV was chosen. The maximum CGV, 2.346 × 106, was obtained at (660, 530, 507, 465) nm. The maximum light efficiency was also determined. A trade-off between CGV and light efficiency should be made according to the requirement of the devices. This study provides guidance for the construction of a four-primary laser display system and the optimization of the CGV in multi-primary display systems.