Abstract

In the paper, by studying the ground water heat pump calculation model, the computing platform for heat pump system was established. Through a calculation case, the fluid temperature of ground water heat pump well side and user side, heat pump power consumption and other data were analyzed by entering relevant parameters, which provide an approach for engineering design and operation prediction, and for the thermodynamic analysis of performance of system year by year and prospective study to guide the engineering practice. Introduction By using renewable energy, the ground source heat pump system can effectively achieve the building energy-saving. As one of the forms of ground source heat pump system, the ground water heat pump system is widely applied in the areas with rich underground aquifer [1]. Through studying dynamic heat transfer mechanics of the underground pumping well groups, and developing calculation module and calculation platform, this paper is conductive to the application of the water-source heat pump systems on a large scale. It is expected to provide technical support for practical engineering design and operation prediction so as to guide engineering practice by means of further studying the calculation method of ground water heat pump system operation process. The calculation method The ground water heat pump system has developed rapidly in China for the past few years, and its architectural scale and application range become wider and wider. The variation of temperature field in the underground aquifer directly determines the operation effect of water source heat pump air conditioning unit. In addition, the heat transport of aquifer, and researches on engineering operating condition prediction are prerequisites for the sustainable and stable operation under complex pumping operating conditions. The component devices of water source heat pump system should be simplified for the sake of establishing calculation platform of the ground water heat pump system [2]. Fig.1 shows the system diagram of the ground water heat pump, which includes the ground water heat exchange system as well as the primary water loop system, the secondary water loop system and terminal air-conditioning system of the heat exchanger. The specific equipment components are described in the following diagram. Under winter operating conditions, ground water heat is transferred from the primary water loop system to the secondary water loop system through plate heat exchanger, the secondary water loop fluid flows through the evaporator of heat pump unit heat pump while the terminal air-conditioning system flows through the condenser of heat pump unit to provide heat for the indoors International Industrial Informatics and Computer Engineering Conference (IIICEC 2015) © 2015. The authors Published by Atlantis Press 1939 of buildings. Under summer operating conditions, the terminal air-conditioning system flows through the evaporator of the heat pump to provide cooling load for the indoors of buildings, the secondary water loop fluid flows through the condenser of heat pump unit to provide heat for the ground through the plate heat exchanger. Fig.1 The ground water heat pump system 1ground water heat exchanger system 2water-source heat pump3heating medium (cooling medium) pipeline system 4user air-conditioning system 1— pumping well group 2—recharging well group 3—submersible pump 4—sand eliminator 5—plate heat exchanger 6—the primary water loop system 7—the secondary water loop system 8—secondary water pipeline constant pressure arrangement 9—secondary water-circulating pump 10—filling water valve of the secondary water loop 11—conversion valve group 12—exchanging valving set 13—blow-down and drain valve 14—blow-down and lifting valve 15—heating medium (cooling medium) circulating pump 16—the constant pressure arrangement of heating medium (cooling medium) pipeline system 17—make-up water valve of the heating medium (cooling medium) pipeline system 18—make-up water pump 19—make-up water tank 20—water processing system 21—water-dividing jar 22—water-collecting jar 23—building The ground water heat pump system can be simplified as shown in Fig.2, with main equipments of plate heat exchanger and heat pump unit. In addition, reservoir balancing also can be added in the system (see Fig.3) to control it by using temperature or temperature difference. When the system load (or the fluid temperature difference of pumping irrigation wells side) is small, reservoir balancing circulating pump can be started rather than pumping irrigation wells pump. When the ground water quality meets the following requirements [3-4] (sand<1/200 000; PH value of 6.5 ~ 8.5; Cao <200mg/L; salinity <3g/L; Cl<100mg/L, SO4<2200mg/L, Fe + <1mg/L, H2S <0.5mg/L), the plate heat exchanger cannot be set and the ground water can directly flow through the evaporator of the heat pump in winter (flow through the condenser of the heat pump in summer ). Taking heat exchange of ground water as an example, this paper discusses the calculation method of the ground water heat pump system operating process. Fig.2 The simplified system Fig.3 The system with reservoir balancing

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call