Abstract

In this study, an attempt to reduce the flow-induced noise generated by heating, ventilation, and air-conditioning (HVAC) systems for commercial electric vehicles using feedback active noise control with real-time filter update in frequency domain was conducted to improve the quietness of a running vehicle. In active noise control (ANC), the frequency-domain gradient descent algorithms (FDGD) to adapt the noises was studied. In the experiment, air conditioner noise was measured using a microphone placed at the driver's left ear and referenced by a microphone at a map lamp for ANC. Results shows that in the 1/3-octave band, the sound pressure level in driver's left ear was 7.2 dB smaller at maximum when the control was operated. The effective frequency bands were between 50 and 150 Hz. Its reduction was 4.7 dB on average.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.