Abstract

This article discussed the temperature field and heat transfer inside catalytic combustion furnace with Pd-based honeycomb monoliths of lean natural gas-air mixtures. The monoliths need to be ignited by gas phase combustion with the excessive air coefficient at 1.63 during the period of start-up process. After local catalytic ignition, a steady state has reached. The temperature field was measured by thermocouple K of diameter 1.0. It was shown that the temperature gradient changed according to the different position inside catalytic combustion furnace. When the furnace was used for heating equipment, heat transfer included mainly heat radiation and convection. For high radiation heat, local surface temperature of monoliths plays a decisive role.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.