Abstract

The inconsistency of the battery modules will lead to overcharging and over-discharging of the grid connected energy storage system. For the modulation strategy of cascaded H-bridge inverter, this paper proposes a new state of charge (SOC) equalization control strategy, which can quickly realize equalization control in one phase and between phases without over-modulation. The simulation results show that the new control strategy has a significant effect, which greatly improves the speed of SOC balancing compared with the traditional SOC equalization control strategy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.